LoRaWAN Pulse Counter – Meter and Consumption Monitoring
ORL-LRW-U-PC — Power supply: Battery
An online price for this product has not been set yet. Share quantities and use case and we will prepare a quote.
This product is priced by quote: add it to your cart and request a single quote together with the other items in your cart.
| Power supply | Battery |
|---|---|
| Power Supply | Internal battery: C-size Li-SOCl2, 8500 mAh |
| Battery Life | 10+ years |
| Sleep Current | < 3 µA |
| Battery Monitoring | Voltage, estimated remaining percentage, low battery warning (adjustable threshold) |
ORL-LRW-U-PCS — Power supply: External
An online price for this product has not been set yet. Share quantities and use case and we will prepare a quote.
This product is priced by quote: add it to your cart and request a single quote together with the other items in your cart.
| Power supply | External |
|---|---|
| Power Supply | External 9 … 48 V DC |
Overview
ORL-LRW-U-PC counts the pulse output of devices such as water, gas or electricity meters and flow meters. Counting is done in hardware and continues while the device sleeps. It reports the total count and the increase in the last period over LoRaWAN.
Applications:
- Water, natural gas and electricity meters
- Flow meter systems
- Pulse-based counting on production lines
- Remote meter reading
Models and ordering information:
- ORL-LRW-U-PC — runs on the internal battery.
- ORL-LRW-U-PCS — powered by an external 9 … 48 V DC supply; same firmware, data format and commands.
Meters with a mechanical contact output need an external RC filter to suppress contact bounce. The total count is saved to non-volatile memory once a day; on an unexpected power loss, pulses after the last save may be lost — since total and increase are sent together, the loss is visible on the server. Battery life is a calculated value for the internal battery, a 15-minute reporting interval and good radio coverage; it shortens with a shorter interval and weaker coverage (about 3 years with weak coverage). The information applies to firmware 1.04; technical specifications are subject to change without notice.
Features
- Hardware counting, also while asleep
- Total count and period increase are sent together
- The total count is saved to non-volatile memory once a day
- LoRaWAN 1.0.4, EU868 — up to 10 km range in open terrain
- Calculated battery life on the internal battery: 10+ years
- IP67 ingress protection
- Remote configuration: reporting interval, alarm and other settings are changed over the network
- Model option with external 9 … 48 V DC supply (ORL-LRW-U-PCS)
Technical specifications
| Pulse Input | Open collector / NPN output · up to 4 kHz |
|---|---|
| Total Count | 32 bit |
| Increase in Period | 16 bit (capped at 65535) |
| Additional Measurements | Battery voltage, supply input voltage, internal device temperature, remaining battery percentage |
| Protocol | LoRaWAN 1.0.4 · OTAA · ADR |
| Band | EU868 |
| Device Class | Class A |
| Transmit Power | Up to 16 dBm EIRP (EU868 limit), automatic with ADR |
| Range | Up to 10 km in open terrain (line of sight; depends on gateway and antenna conditions) |
| Antenna | Internal; external antenna optional (effective antenna gain remotely adjustable) |
| Dimensions (W x L x H) | 65mm x 154mm x 59mm |
| Ingress Protection | IP67 |
|---|---|
| Operating Temperature | −10 … +85 °C |
| Cable Length | ~50–100 cm (customizable) |
| Reporting Interval | 1 … 254 minutes, set remotely (default 15 min) |
| Timestamp | On every measurement once network time is received, for the time of measurement |
| Confirmed Uplinks | Optional; during a connection outage up to 2000 measurements are stored in the device and sent when the connection returns |
| Diagnostics | Restart cause and daily status report |
| On-Site Use | Start, restart and factory reset with a magnet; audible feedback (can be turned off) |
| Integration | Ready-made data decoding with the ORELTEK codec (standard LoRaWAN JavaScript codec interface) |
| Firmware | 1.04 |
| Warranty | 2 years |